Yayın:
Examination of strength reduction factor in CFRP-confined columns under axial compression

dc.contributor.authorTekin Ozer, Aysun
dc.contributor.authorAlacali, Sema
dc.contributor.institutionauthorALACALI, Sema
dc.date.accessioned2026-06-27T14:58:52Z
dc.date.issued2024
dc.description.abstractIn the strength design method, the safety level is tried to be reached by using strength reduction factors phi applied to the nominal strengths. In the current ACI 318-19, the safety factors phi are suggested as 0.65 for tie-reinforced concrete columns and 0.60 for plain columns, respectively. The aim of the present study is to evaluate the strength reduction factors of the confined columns with Carbon Fiber Reinforced Polymer (CFRP) subjected to axial compression load according to ACI 318-19. For this purpose, a total of 298 column test specimens with circular and rectangular cross-sections confined with CFRP collected from 18 different experimental studies in the literature were examined to determine the strength reduction factors. The first-order second-moment approach was used to determine these factors by reliability analysis, and the correlation effects between random variables were not taken into account. The target reliability index and the corresponding probability of failure were taken as beta =3.5 and p(F) = 2.33x10(-4) for different coefficients of variation of random variables, respectively. Then, these factors were been separately compared to those of recommended in the ACI 318-19. At the end of the study, the upper limits of the coefficients of variation that should not be exceeded were determined to ensure the target reliability of the columns.en
dc.description.urihttps://doi.org/10.14744/sigma.2024.0003636
dc.identifier.doi10.14744/sigma.2024.0003636
dc.identifier.eissn1304-7191
dc.identifier.endpage382
dc.identifier.issn1304-7205
dc.identifier.issue2
dc.identifier.startpage366
dc.identifier.urihttps://hdl.handle.net/20.500.14981/66715
dc.identifier.volume42
dc.identifier.wos001315860600006
dc.language.isoeng
dc.publisherYILDIZ TECHNICAL UNIV
dc.relation.ispartofSIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI
dc.subjectStrength Reduction Factor
dc.subjectCarbon Fiber Reinforced Polymer
dc.subjectFirst-order Second- moment Approach
dc.subjectAxial load
dc.subjectColumn
dc.subjectSQUARE CONCRETE COLUMNS
dc.subjectRELIABILITY-BASED DESIGN
dc.subjectRC COLUMNS
dc.subjectFRP
dc.subjectBEHAVIOR
dc.subjectPERFORMANCE
dc.subjectCALIBRATION
dc.subjectMODEL
dc.subjectEngineering
dc.titleExamination of strength reduction factor in CFRP-confined columns under axial compression