Experimental investigation of heat transfer and pressure drop of fin and tube heat exchanger under dry and wet conditions

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER

DOI

10.1016/j.ijthermalsci.2022.107580

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

The heat transfer and pressure drop characteristics of nine flat plate finned tube heat exchangers have been experimentally investigated under dry and wet conditions. The effect of five parameters is evaluated for wet conditions: number of tube row (2, 4, 6), fin pitch (2, 3, 4 mm), frontal air velocity (1, 2, 3 m/s), temperature (25, 30, 35 degrees C), and relative humidity (60, 70, 80). The Box-Behnken Design (BBD) is used to determine minimum candidate test points of the experimental studies, and more experiments have been carried out to determine the effects more sensitively. For nine heat exchangers, the effect of frontal air velocity (1, 2, 3 m/s) is evaluated for dry conditions. (The Reynolds number ranged from 300 to 2150 for both conditions.) Response Surface Model (RSM) has been used to evaluate the Colburn j factor and Fanning friction f factor for dry and wet conditions. The results show that the j factor decreases with increasing front air velocity and number of tube rows, while the j factor increases with increasing fin pitch, air temperature, and relative humidity for wet conditions. In addition, the f factor decreases with increasing front air velocity, number of tube rows and fin pitch, while the f factor increases with increasing air temperature and relative humidity. For dry conditions, the j factor decreases with increasing front air velocity and number of tube rows, while the j factor increases with increasing fin pitch. In addition, the f factor decreases with increasing front air velocity, number of tube rows, while the f factor increases with increasing fin pitch. The j factor and f factor values are higher under wet conditions than dry conditions. Three correlations are proposed for the j and f factors under dry and wet conditions. For wet conditions, the best mean deviation for the j factor is 8.3%, whereas the best mean deviation for the f factor is 10.9%. For dry conditions, the best mean deviation for the j factor is 8.3%, whereas the best mean deviation for the f factor is 8.2%. The experimental results are compared with the proposed and literature correlations. Compared to the correlations obtained in literature studies using similar geometric parameters in the study, the proposed correlation has gave better results. Even at the values of geometric parameters which literature correlations are failed, the proposed correlations has gave good results.

Tanım

Dergi veya Seri

INTERNATIONAL JOURNAL OF THERMAL SCIENCES

ISSN

1290-0729

ISBN

Haklar

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads