Yayın: A novel determination method for diuron in seaweed samples: Combination of quadruple isotope dilution strategy with liquid chromatography - quadrupole time of flight - tandem mass spectrometry for superior accuracy and precision
| dc.contributor.author | Tekin, Zeynep | |
| dc.contributor.author | Er, Elif Ozturk | |
| dc.contributor.author | Gunkara, Omer Tahir | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.date.accessioned | 2026-06-27T14:26:59Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | This paper proposed an accurate and sensitive analytical method based on the combination of Liquid Chromatography-Quadrupole Time of Flight-Tandem Mass Spectrometry (LC-QTOF-MS/MS) system with Quadruple Isotope Dilution-Mass Spectrometry ((IDMS)-M-4) strategy for the determination of diuron at trace levels. In order to achieve accurate and reliable determination of the analyte, (IDMS)-M-4 strategy that uses stable isotopically labelled analogues was employed. Diuron-d6 was synthesized in the laboratory using a novel strategy and employed in (IDMS)-M-4 for the preparation of three calibration blends and seaweed sample blend. The analytical performance of the LC-QTOF-MS/MS method was evaluated and the respective detection and quantification limits obtained were 14.6 mu g kg(-1) and 46.5 mu g kg(-1). Good linearity was obtained with a correlation coefficient of 0.9995 over the dynamic range from 50 to 1000 mu g kg(-1). The validity of the method was successfully tested by carrying out spiking experiments in seaweed samples. The percent recovery value showed superior enhancement for (IDMS)-M-4 strategy (99.97 +/- 0.41%) confirming the applicability of the method to complex matrices with great accuracy and precision. (C) 2019 Elsevier B.V. All rights reserved. | en |
| dc.description.uri | https://doi.org/10.1016/j.chroma.2019.460612 | |
| dc.identifier.doi | 10.1016/j.chroma.2019.460612 | |
| dc.identifier.eissn | 1873-3778 | |
| dc.identifier.issn | 0021-9673 | |
| dc.identifier.pubmed | 31623845 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/60754 | |
| dc.identifier.volume | 1611 | |
| dc.identifier.wos | 000510312700023 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER | |
| dc.relation.ispartof | JOURNAL OF CHROMATOGRAPHY A | |
| dc.subject | Diuron | |
| dc.subject | Isotope dilution | |
| dc.subject | Seaweed | |
| dc.subject | Mass spectrometry | |
| dc.subject | SURFACE-WATER | |
| dc.subject | HERBICIDES | |
| dc.subject | EXTRACTION | |
| dc.subject | PESTICIDES | |
| dc.subject | MS/MS | |
| dc.subject | ESI | |
| dc.subject | MS | |
| dc.subject | Biochemistry & Molecular Biology | |
| dc.subject | Chemistry | |
| dc.title | A novel determination method for diuron in seaweed samples: Combination of quadruple isotope dilution strategy with liquid chromatography - quadrupole time of flight - tandem mass spectrometry for superior accuracy and precision | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |