Yayın:
SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANT (BHA AND BHT) CONCENTRATIONS IN PHARMACEUTICAL PREPARATIONS AND CHEWING GUMS USING THE H-POINT STANDARD ADDITION METHOD

dc.contributor.authorOzgur, Mahmure
dc.contributor.authorKalaycioglu, Zeynep
dc.contributor.authorDulger, Oznur
dc.date.accessioned2026-06-27T14:12:01Z
dc.date.issued2017
dc.description.abstractA simple, rapid, and sensitive spectrophotometric method was developed for the simultaneous determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) concentration in pharmaceutical preparations and chewing gums, without prior separation steps, using the H-point standard addition method (HPSAM). The concentration of one antioxidant was calculated by overlapping spectra at two appropriately selected wavelengths at which the interferent, other antioxidant, should has the same absorbance value. Absorbances at two pairs of wavelengths, 265 and 288 nm (with BHA as analyte) or 288 and 293 nm (with BHT as analyte) were monitored, while adding standard solutions of BHA or BHT, respectively. Calibration graphs were determined at 4-20 mu gml(-1) (r = 0.9981) for BHA and 20-100 mu gml(-1) (r = 0.9940) for BHT in binary mixtures. The proposed method was tested and validated using various parameters according to ICH guidelines. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.48 and 1.51 mu gml(-1) for BHA and 0.72 and 2.41 mu gml(-1) for BHT, respectively. The percentage recovery ranges were 100.44-102.50 % for BHA and 96.45-100.04 % for BHT, with relative standard deviations (RSD) less than 1.48 % indicating reasonable repeatability of the method. The intra-day and inter-day precision tests showed reliable RSD values (< 2 %). The results obtained using HPSAM were statistically compared with results obtained using the derivative spectrophotometric method that was previously reported by us, showing high similarity between results.en
dc.description.urihttps://doi.org/10.20450/mjcce.2017.1330
dc.identifier.doi10.20450/mjcce.2017.1330
dc.identifier.eissn1857-5625
dc.identifier.endpage222
dc.identifier.issn1857-5552
dc.identifier.issue2
dc.identifier.startpage211
dc.identifier.urihttps://hdl.handle.net/20.500.14981/57861
dc.identifier.volume36
dc.identifier.wos000419637600002
dc.language.isoeng
dc.publisherSOC CHEMISTS TECHNOLOGISTS MADECONIA
dc.relation.ispartofMACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING
dc.rightsopenAccess
dc.subjectH-point standard addition method
dc.subjectphenolic antioxidants
dc.subjectspectrophotometry
dc.subjectbutylated hydroxyanisole
dc.subjectbutylated hydroxytoluene
dc.subjectpharmaceutical preparations
dc.subjectchewing gums
dc.subjectELECTROKINETIC CAPILLARY CHROMATOGRAPHY
dc.subjectANODIC-STRIPPING VOLTAMMETRY
dc.subjectEDIBLE OILS
dc.subjectSYNTHETIC ANTIOXIDANTS
dc.subjectLIQUID-CHROMATOGRAPHY
dc.subjectMASS SPECTROMETRY
dc.subjectPONCEAU 4R
dc.subjectF344 RATS
dc.subjectEXTRACTION
dc.subjectChemistry
dc.subjectEngineering
dc.titleSIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANT (BHA AND BHT) CONCENTRATIONS IN PHARMACEUTICAL PREPARATIONS AND CHEWING GUMS USING THE H-POINT STANDARD ADDITION METHOD
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar