Yayın:
Determination of Copper in Quince Samples with a Matrix Matching Strategy Using Vortex Assisted Deep Eutectic Solvent-Based Emulsification Liquid Phase Microextraction - Slotted Quartz Tube - Flame Atomic Absorption Spectrometry

dc.contributor.authorBorahan, Tulay
dc.contributor.authorUnutkan, Tugce
dc.contributor.authorZaman, Buse Tugba
dc.contributor.authorBakirdere, Emine Gulhan
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:28:14Z
dc.date.issued2020
dc.description.abstractA vortex assisted deep eutectic solvent-based emulsification liquid-phase microextraction method was developed for the extraction and preconcentration of copper at trace levels followed by determination with slotted quartz tube - flame atomic absorption spectrometry. Various experimental factors were systematically optimized by performing single variant experiments to enhance detection power. Under the optimized conditions, the calibration plot showed linearity in the concentration range from 2.5 to 100 mu g L-1. The developed method offered limits of detection and quantification equal to 0.5 and 1.8 mu g L-1, respectively. The relative standard deviation (n = 6) for the lowest concentration of the calibration plot was lower than 6.0% which demonstrates good precision. The enhancement in the detection power was 160-fold by the developed vortex assisted deep eutectic solvent-based emulsification liquid phase microextraction - slotted quartz tube - flame atomic absorption spectrometry method. The validity and accuracy of the proposed method were confirmed through recovery experiments on quince samples. Acceptable percent recoveries in the range from 93.6 to 117.6% were obtained.en
dc.description.urihttps://doi.org/10.1080/00032719.2020.1757689
dc.identifier.doi10.1080/00032719.2020.1757689
dc.identifier.eissn1532-236X
dc.identifier.endpage2760
dc.identifier.issn0003-2719
dc.identifier.issue17
dc.identifier.startpage2748
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60972
dc.identifier.volume53
dc.identifier.wos000532186200001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectCopper
dc.subjectdeep eutectic solvent
dc.subjectflame atomic absorption spectrometry
dc.subjectliquid-phase microextraction
dc.subjectCLOUD POINT EXTRACTION
dc.subjectCOLORIMETRIC DETERMINATION
dc.subjectWATER SAMPLES
dc.subjectLEAD
dc.subjectMERCURY
dc.subjectGREEN
dc.subjectZINC
dc.subjectPRECONCENTRATION
dc.subjectVEGETABLES
dc.subjectADSORBENT
dc.subjectChemistry
dc.titleDetermination of Copper in Quince Samples with a Matrix Matching Strategy Using Vortex Assisted Deep Eutectic Solvent-Based Emulsification Liquid Phase Microextraction - Slotted Quartz Tube - Flame Atomic Absorption Spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar