Yayın: In situ atom trapping of Bi on W-coated slotted quartz tube flame atomic absorption spectrometry and interference studies
| dc.contributor.author | Kilinc, Ersin | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.contributor.author | Aydin, Firat | |
| dc.contributor.author | Ataman, O. Yavuz | |
| dc.contributor.institutionauthor | BAKIRDERE, Sezgin | |
| dc.date.accessioned | 2026-06-27T13:23:59Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | Analytical performances of metal coated slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) and slotted quartz tube in situ atom trapping flame atomic absorption spectrometry (SQT-AT-FAAS) systems were evaluated for determination of Bi. Non-volatile elements such as Mo, Zr, W and Ta were tried as coating materials. It was observed that W-coated SQT gave the best sensitivity for the determination of Bi for SQT-FAAS and SQT-AT-FMS. The parameters for W-coated SQT-FAAS and W-coated SQT-AT-FAAS were optimized. Sensitivity of FAAS for Bi was improved as 4.0 fold by W-coated SQT-FAAS while 613 fold enhancement in sensitivity was achieved by W-coated SQT-AT-FAAS using 5.0 min trapping with respect to conventional FAAS. MIBK was selected as organic solvent for the re-atomization of Bi from the trapping surface. Limit of detection values for W-coated SQT-FAAS and W-coated SQT-AT-FAAS was obtained as 0.14 mu g mL(-1) and 0.51 ng mL(-1), respectively. Linear calibration plot was obtained in the range of 2.5-25.0 ng mL(-1) for W-coated SQT-AT-FAAS. Accuracy of the W-coated SQT-AT-FAAS system was checked by analyzing a standard reference material, NIST 1643e. (C) 2013 Elsevier B.V. All rights reserved. | en |
| dc.description.sponsorship | University of Dicle (DUBAP) [10-FF-31] | |
| dc.description.sponsorship | TUBITAK-BIDEP | |
| dc.description.uri | https://doi.org/10.1016/j.sab.2013.08.008 | |
| dc.identifier.doi | 10.1016/j.sab.2013.08.008 | |
| dc.identifier.endpage | 19 | |
| dc.identifier.issn | 0584-8547 | |
| dc.identifier.startpage | 14 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/52639 | |
| dc.identifier.volume | 89 | |
| dc.identifier.wos | 000327367000003 | |
| dc.language.iso | eng | |
| dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | |
| dc.relation.ispartof | SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY | |
| dc.rights | openAccess | |
| dc.subject | Metal coating | |
| dc.subject | Bismuth | |
| dc.subject | In situ atom trapping | |
| dc.subject | Atomic absorption spectrometry | |
| dc.subject | Slotted quartz tube | |
| dc.subject | HYDRIDE-GENERATION | |
| dc.subject | SENSITIVITY IMPROVEMENT | |
| dc.subject | ONLINE PRECONCENTRATION | |
| dc.subject | LEAD | |
| dc.subject | CADMIUM | |
| dc.subject | ANTIMONY | |
| dc.subject | ELEMENTS | |
| dc.subject | SAMPLES | |
| dc.subject | COPPER | |
| dc.subject | Spectroscopy | |
| dc.title | In situ atom trapping of Bi on W-coated slotted quartz tube flame atomic absorption spectrometry and interference studies | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |