Yayın:
Effect of void fraction and friction factor models on the prediction of pressure drop of R134a during downward condensation in a vertical tube

dc.contributor.authorDalkilic, A. S.
dc.contributor.authorKurekci, N. A.
dc.contributor.authorWongwises, S.
dc.contributor.institutionauthorKÜREKCİ, Nuri Alpay
dc.contributor.institutionauthorDALKILIÇ, Ahmet Selim
dc.date.accessioned2026-06-27T13:17:51Z
dc.date.issued2012
dc.description.abstractThe theoretical flow models of homogeneous and separated flow are applied to in-tube condensation to predict the pressure drop characteristics of R134a. The homogeneous flow model is modified by ten different dynamic viscosity correlations and various alternative correlations of total, frictional and momentum pressure drops to take account of the partial condensation inside the tube. Numerical analyses were performed to determine the average and local homogeneous wall shear stresses and friction factors by means of a CFD program. The equivalent Reynolds number model is modified by six different two-phase friction factors to determine the total condensation pressure drop in the separated flow model. The refrigerant side total pressure drops, frictional pressure drops, friction factors and wall shear stresses are determined within a +/- 30% error band. The importance of using the alternative total, momentum and frictional pressure drop correlations for the homogeneous flow model is also shown.en
dc.description.sponsorshipKing Mongkut's University of Technology Thonburi (KMUTT)
dc.description.sponsorshipThailand Research Fund
dc.description.sponsorshipNational Research University
dc.description.urihttps://doi.org/10.1007/s00231-011-0854-0
dc.identifier.doi10.1007/s00231-011-0854-0
dc.identifier.endpage139
dc.identifier.issn0947-7411
dc.identifier.issue1
dc.identifier.startpage123
dc.identifier.urihttps://hdl.handle.net/20.500.14981/51601
dc.identifier.volume48
dc.identifier.wos000300084400011
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofHEAT AND MASS TRANSFER
dc.subjectLIQUID ANNULAR-FLOW
dc.subject2-PHASE FLOW
dc.subjectHEAT-TRANSFER
dc.subjectAIR-WATER
dc.subjectHORIZONTAL TUBES
dc.subjectMINICHANNELS
dc.subjectTRANSITION
dc.subjectVISCOSITY
dc.subjectHOLDUP
dc.subjectR-410A
dc.subjectThermodynamics
dc.subjectMechanics
dc.titleEffect of void fraction and friction factor models on the prediction of pressure drop of R134a during downward condensation in a vertical tube
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar