Yayın:
Development of a sensitive liquid-liquid extraction method for the determination of N-butyryl-L-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard

dc.contributor.authorBakaraki, Nouha
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBakirdere, Sezgin
dc.contributor.authorEngin, Guleda Onkal
dc.contributor.institutionauthorENGİN, Güleda
dc.contributor.institutionauthorBAKIRDERE, Sezgin
dc.date.accessioned2026-06-27T13:47:50Z
dc.date.issued2016
dc.description.abstractQuorum sensing is defined as the bacterial communication through sending and receiving chemical signals such as N-acyl homoserine lactone (AHL) and oligopeptide for Gram negative bacteria and Gram positive bacteria, respectively. This mysterious bacterial interaction regulates a wide range of activities affecting the environment, agriculture, and therefore, humans. In the last century, quorum sensing investigations trying to follow and measure these chemical signals have accelerated. In this study, an analytical method was developed and optimized in order to extract and measure one of the AHLs: N-butyryl-L-homoserine lactone (C4-HSL) by gas chromatography-mass spectrometry (GC-MS). The aim of the study was to develop a method that increases the sensitivity and precision of AHL detection by GC-MS due to the problem in the determination of analytes in wastewater which have a complex matrix. The limits of detection and quantification obtained for C4-HSL were 12.9 ng mL(-1) and 43.3 ng mL(-1), respectively. The precision of the method was improved upon using deuterated anthracene as the internal standard, which gave a lower relative standard deviation compared to that without the internal standard.en
dc.description.urihttps://doi.org/10.1039/c6ay00317f
dc.identifier.doi10.1039/c6ay00317f
dc.identifier.eissn1759-9679
dc.identifier.endpage2665
dc.identifier.issn1759-9660
dc.identifier.issue12
dc.identifier.startpage2660
dc.identifier.urihttps://hdl.handle.net/20.500.14981/54927
dc.identifier.volume8
dc.identifier.wos000372758000014
dc.language.isoeng
dc.publisherROYAL SOC CHEMISTRY
dc.relation.ispartofANALYTICAL METHODS
dc.subjectSOLID-PHASE EXTRACTION
dc.subjectSENSING SIGNAL MOLECULES
dc.subjectACYLHOMOSERINE LACTONES
dc.subjectCHROMOBACTERIUM-VIOLACEUM
dc.subjectPSEUDOMONAS-AERUGINOSA
dc.subjectQUANTIFICATION
dc.subjectMICROEXTRACTION
dc.subjectPURIFICATION
dc.subjectBACTERIA
dc.subjectMODEL
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.subjectSpectroscopy
dc.titleDevelopment of a sensitive liquid-liquid extraction method for the determination of N-butyryl-L-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar