Yayın:
Assessment of indoor air pollution exposure in urban hospital microenvironments

dc.contributor.authorMohammadyan, Mahmoud
dc.contributor.authorKeyvani, Sepideh
dc.contributor.authorBahrami, Ali
dc.contributor.authorYetilmezsoy, Kaan
dc.contributor.authorHeibati, Behzad
dc.contributor.authorPollitt, Krystal J. Godri
dc.date.accessioned2026-06-27T14:23:15Z
dc.date.issued2019
dc.description.abstractHospitals are microenvironments containing populations with potentially enhanced sensitivity to air pollution. The objectives of this study were to characterize the concentration of indoor and outdoor size-fractionated particulate matter (PM) at two urban hospital sites in Kashan, Iran, and to evaluate the relationship between indoor and outdoor PM levels. PM1.0, PM2.5, and PM10 concentrations were measured over a 3-month period outside each hospital with parallel sampling at four indoor locations in patient wards. The results indicated that mean indoor concentrations at the sampling sites (PM1.0=17.8g/m(3), PM2.5=45.5g/m(3), and PM10=162.7g/m(3)) were found to be lower than outdoors levels (PM1.0=20.6g/m(3), PM2.5=62.1g/m(3), and PM10=300.6g/m(3)). Outdoor and indoor PM mass concentrations were associated with PM1.0, PM2.5, and PM10.0. Ambient wind speed also influenced the indoor/outdoor relationship for PM1.0 and PM2.5 but not for PM10. The average I/O ratios for PM2.5 in the intensive care unit (ICU) and children's ward at Shahid Beheshti Hospital were close to or above 1.00. Indoor PM1.0 and PM2.5 concentrations were found to be positively associated with outdoor PM1.0 and PM2.5 concentrations, but no relationship was observed with PM10. The present findings may inform policymakers in implementing evidence-based efforts for the aim of improving the indoor air quality in closed and confined spaces.en
dc.description.sponsorshipMazandaran University of Medical Sciences [93-7225]
dc.description.urihttps://doi.org/10.1007/s11869-018-0637-6
dc.identifier.doi10.1007/s11869-018-0637-6
dc.identifier.eissn1873-9326
dc.identifier.endpage159
dc.identifier.issn1873-9318
dc.identifier.issue2
dc.identifier.startpage151
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60023
dc.identifier.volume12
dc.identifier.wos000458121600003
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofAIR QUALITY ATMOSPHERE AND HEALTH
dc.subjectIndoor air quality
dc.subjectPM2
dc.subject5
dc.subjectPM10
dc.subjectHospitals
dc.subjectIran
dc.subjectLOWER RESPIRATORY-INFECTIONS
dc.subjectPARTICULATE MATTER
dc.subjectPM2.5
dc.subjectPARTICLES
dc.subjectWINTER
dc.subjectEnvironmental Sciences & Ecology
dc.titleAssessment of indoor air pollution exposure in urban hospital microenvironments
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar