Yayın:
Differential Pulse Voltammetric Determination of Folic Acid Using a Poly(Cystine) Modified Pencil Graphite Electrode

dc.contributor.authorDokur, Ebrar
dc.contributor.authorGorduk, Ozge
dc.contributor.authorSahin, Yucel
dc.date.accessioned2026-06-27T14:28:06Z
dc.date.issued2020
dc.description.abstractThe electropolymerization of L-cystine was performed on a pencil graphite electrode (PGE) in order to improve the redox properties for the determination of folic acid (FA). The characterization studies of the poly(cystine)/PGE were performed by cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The surface morphology of the poly(cystine)/PGE was examined by scanning electron microscopy (SEM). The performance of poly(cystine)/PGE for the determination of folic acid was investigated using differential pulse voltammetry (DPV) and cyclic voltammetry (CV). According to the results, the electrochemical response of folic acid increased significantly on the poly(cystine)/PGE. The poly(cystine)/PGE showed a linear response for the concentrations range from 1.0 mu M to 100 mu M for the oxidation of folic acid. The (poly(cystine)/PGE) demonstrated a favorable sensitivity for the electrochemical determination of folic acid. The limits of detection (LOD) and quantitation (LOQ) were determined to be 0.43 mu M and 1.45 mu M at signal-to-noise ratios of 3 and 10, respectively. The determination of folic acid was successfully performed on the poly(cystine)/PGE in orange juice.en
dc.description.urihttps://doi.org/10.1080/00032719.2020.1728540
dc.identifier.doi10.1080/00032719.2020.1728540
dc.identifier.eissn1532-236X
dc.identifier.endpage2078
dc.identifier.issn0003-2719
dc.identifier.issue13
dc.identifier.startpage2060
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60947
dc.identifier.volume53
dc.identifier.wos000514504100001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectFolic acid (FA)
dc.subjectpoly(cystine)
dc.subjectpencil graphite electrode (PGE)
dc.subjectcyclic voltammetry (CV)
dc.subjectdifferential pulse voltammetry (DPV)
dc.subjectGLASSY-CARBON ELECTRODE
dc.subjectASCORBIC-ACID
dc.subjectURIC-ACID
dc.subjectELECTROCHEMICAL DETERMINATION
dc.subjectLEVEL DETERMINATION
dc.subjectGOLD NANOPARTICLES
dc.subjectPASTE ELECTRODE
dc.subjectONE-STEP
dc.subjectNANOTUBES
dc.subjectDOPAMINE
dc.subjectChemistry
dc.titleDifferential Pulse Voltammetric Determination of Folic Acid Using a Poly(Cystine) Modified Pencil Graphite Electrode
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar