Yayın:
Accurate determination of amino acids by quadruple isotope dilution-reverse phase liquid Chromatography-Tandem mass spectrometry after derivatization with 2-Naphthoyl chloride

dc.contributor.authorEr, Elif Ozturk
dc.contributor.authorErarpat, Sezin
dc.contributor.authorBodur, Suleyman
dc.contributor.authorGunkara, Omer Tahir
dc.contributor.authorOzbek, Belma
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:45:15Z
dc.date.issued2022
dc.description.abstractThe determination of amino acids in biological samples is central to the diagnosis of inherited metabolic disorders and also gives significant information about the metabolisms in the cells and living body. The development of analytical method for reliable quantification of amino acids in biological samples is still challenging because of the polar nature of amino acids and complex nature of biological samples causing a high degree of interferences during analysis. In the present study, a pre-column derivatization method using 2-naphtoyl chloride combined with liquid chromatography-tandem mass spectrometry method was developed for the determination of 17 amino acids in human serum and urine matrices. Low detection limits were obtained in the range of 0.015 - 0.266 mu mol kg(-1) and acceptable recovery results were obtained in human serum and urine samples. Isotopically labelled (N-15 labelled) amino acids were spiked to standards and samples before derivatization to compensate for the analytical errors in the whole procedure. The combination of quadrupole isotope dilution strategy with the derivatization based reversed phase chromatography allowed to improve method accuracy and precision. (c) 2022 Elsevier B.V. All rights reserved.en
dc.description.sponsorshipYildiz Technical University [FDK-2017-3186]
dc.description.urihttps://doi.org/10.1016/j.chroma.2022.462870
dc.identifier.doi10.1016/j.chroma.2022.462870
dc.identifier.eissn1873-3778
dc.identifier.issn0021-9673
dc.identifier.pubmed35176687
dc.identifier.urihttps://hdl.handle.net/20.500.14981/64343
dc.identifier.volume1667
dc.identifier.wos000755173600010
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofJOURNAL OF CHROMATOGRAPHY A
dc.subjectAmino acids
dc.subjectDerivatization
dc.subjectHuman serum
dc.subjectHuman urine
dc.subjectIsotope dilution
dc.subjectQUANTITATIVE-ANALYSIS
dc.subjectQUANTIFICATION
dc.subjectOPTIMIZATION
dc.subjectSINGLE
dc.subjectBiochemistry & Molecular Biology
dc.subjectChemistry
dc.titleAccurate determination of amino acids by quadruple isotope dilution-reverse phase liquid Chromatography-Tandem mass spectrometry after derivatization with 2-Naphthoyl chloride
dc.typeArticle
dspace.entity.typePublication