Experimental Investigation of the Effects of Helical Roof on the Performance of Stairmand High Efficiency Cyclone

dc.contributor.authorKaradeniz, Aykut
dc.contributor.authorDemir, Selami
dc.date.accessioned2026-06-27T14:36:37Z
dc.date.issued2021
dc.description.abstractCost-effectiveness of a standard and a modified Stairmand high-efficiency type cyclone was compared at various inlet gas velocities. The modified design was obtained by replacing the roof of the standard design with a helical roof. Experiments were conducted by both standard and helical roof designs at the same operating conditions. Results showed that helical roof leads to reduced pressure drop in cyclones while having a negative impact on particle collection efficiency. Reductions in pressure drop can reach up to 30%, while particle collection efficiency is reduced by up to 8% simultaneously. Overall, the treatment cost of a cyclone separator can be reduced by 14.1-20.8%. Results indicated that helical roof design cyclones can be used to reduce overall treatment cost by cyclone separators.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [116Y061]
dc.description.urihttps://doi.org/10.1155/2021/7207994
dc.identifier.doi10.1155/2021/7207994
dc.identifier.eissn1687-8078
dc.identifier.issn1687-806X
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62635
dc.identifier.volume2021
dc.identifier.wos000715773800001
dc.language.isoeng
dc.publisherWILEY
dc.relation.ispartofINTERNATIONAL JOURNAL OF CHEMICAL ENGINEERING
dc.rightsopenAccess
dc.subjectPRESSURE-DROP
dc.subjectFLOW PATTERN
dc.subjectINLET ANGLE
dc.subjectOPTIMIZATION
dc.subjectCFD
dc.subjectDIMENSIONS
dc.subjectGEOMETRY
dc.subjectLENGTH
dc.subjectEngineering
dc.titleExperimental Investigation of the Effects of Helical Roof on the Performance of Stairmand High Efficiency Cyclone