Yayın:
Flow Injection Potentiometric Determination of Silver(I) in Photographic Film Developing Solution Samples by Polyvinylchloride Membrane Silver(I) Selective Electrode

dc.contributor.authorTopcu, Cihan
dc.contributor.authorColdur, Fatih
dc.contributor.authorAndac, Muberra
dc.contributor.authorCubuk, Osman
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorCaglar, Bulent
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T13:59:26Z
dc.date.issued2016
dc.description.abstractA polyvinylchloride (PVC) membrane silver(I) selective electrode was developed for the determination of silver(I) ions in photographic film developing solutions. The electrode was embedded into a home-made flow cell and successfully used as a potentiometric detector in a flow injection potentiometric (FIP) system. Under the optimized flow injection conditions, the electrode exhibited a non-Nernstian slope of 67.20 +/- 0.80 mV in the linear range from 1.0x10(-5) to 1.0x10(-1) mol/L (R-2 = 0.9961) and the lowest value for limit of detection (LOD) was calculated as 7.1x10(-6) mol/L. The electrode displayed good sensitivity, selectivity, repeatable and rapid response towards silver(I) ions. Lifetime of the electrode was determined as at least two months in FIP system. The electrode was also successfully applied for the potentiometric determination of silver(I) ions in photographic film developing solution samples in FIP system. The results attained from FIP system were compared with the atomic absorption spectrophotometry (AAS) results by using student's t-test at 95 % confidence level and relative deviation (RD) between the two methods was < 8 %.en
dc.identifier.endpage888
dc.identifier.issn0253-5106
dc.identifier.issue5
dc.identifier.startpage882
dc.identifier.urihttps://hdl.handle.net/20.500.14981/56320
dc.identifier.volume38
dc.identifier.wos000390364000010
dc.language.isoeng
dc.publisherCHEM SOC PAKISTAN
dc.relation.ispartofJOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN
dc.subjectSilver(I) selective electrode
dc.subjectFlow injection potentiometry
dc.subjectPhotographic film developing solution
dc.subjectPotentiometric analysis
dc.subjectCARBON-PASTE ELECTRODE
dc.subjectPOLY(VINYL CHLORIDE)-MEMBRANE ELECTRODES
dc.subjectPLASMA-MASS-SPECTROMETRY
dc.subjectLOW-LEVEL DETERMINATION
dc.subjectHYDROCHLORIDE
dc.subjectIONOPHORES
dc.subjectSERUM
dc.subjectBATCH
dc.subjectChemistry
dc.titleFlow Injection Potentiometric Determination of Silver(I) in Photographic Film Developing Solution Samples by Polyvinylchloride Membrane Silver(I) Selective Electrode
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar