Yayın:
Determination of cadmium at trace levels in parsley samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with cloud point extraction

dc.contributor.authorKasa, Nursu Aylin
dc.contributor.authorSel, Sabriye
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBalordere, Sezgin
dc.date.accessioned2026-06-27T14:16:35Z
dc.date.issued2019
dc.description.abstractIn this study, a cloud point extraction (CPE) method for the extraction and preconcentration of cadmium was developed with its determination by slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS). Method developed is based on the reaction of cadmium with diphenylcarbazone to form a coordinated hydrophobic ion-associated complex, and subsequent extraction into the surfactant-rich phase of extraction solvent. The main factors affecting the analyte recovery such as volume of surfactant and concentration, equilibrium temperature, eluent type and volume were investigated to obtain optimum extraction conditions. Under the optimum conditions, detection and quantification limits were found to be 0.70 and 2.3 ng mL(-1), respectively. About 60 folds enhancement in detection power for the analyte was recorded over the FAAS instrument. The accuracy and applicability of the method was performed by spiking parsley samples at different concentrations, and the % recovery results were found to be between 93 and 105%. (C) 2019 Elsevier Ltd. All rights reserved.en
dc.description.urihttps://doi.org/10.1016/j.measurement.2019.07.069
dc.identifier.doi10.1016/j.measurement.2019.07.069
dc.identifier.eissn1873-412X
dc.identifier.issn0263-2241
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58695
dc.identifier.volume147
dc.identifier.wos000487249900037
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofMEASUREMENT
dc.subjectCadmium
dc.subjectSQT
dc.subjectFAAS
dc.subjectCloud point extraction
dc.subjectParsley
dc.subjectLIQUID-LIQUID MICROEXTRACTION
dc.subjectONLINE PRECONCENTRATION
dc.subjectPHASE MICROEXTRACTION
dc.subjectBIOLOGICAL SAMPLES
dc.subjectLEAD
dc.subjectCD
dc.subjectSYSTEM
dc.subjectCOPPER
dc.subjectIONS
dc.subjectPB
dc.subjectEngineering
dc.subjectInstruments & Instrumentation
dc.titleDetermination of cadmium at trace levels in parsley samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with cloud point extraction
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar