Yayın:
Performance optimisation of the combined single flash binary geothermal power plant

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

INDERSCIENCE ENTERPRISES LTD

DOI

10.1504/ijex.2011.038518

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

In this paper, the optimal operating conditions of a hypothetical combined single flash-binary geothermal power plant are investigated and performance analyses are performed based on Aydin-Germencik field in Turkey. The relationship between flashing pressure, turbine inlet pressure of the binary cycle and total heat transfer area of the heat exchanger are determined for maximum power output of the combined power plant. According to the results, the optimal flashing pressure of the flash cycle and the optimal inlet pressure of the working fluid to binary cycle's turbine were found to be 500 kPa and 3620 kPa, respectively. In these pressures, the total power output of the combined power plant and the total heat transfer area of the heat exchanger have been calculated as 23,065 kWe and 6924 m(2), respectively.

Tanım

Dergi veya Seri

INTERNATIONAL JOURNAL OF EXERGY

ISSN

1742-8297

ISBN

Haklar

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads