Yayın:
Beam Diagnostics at KAHVE Lab Proton Source and LEBT Line

dc.contributor.authorAciksoz, Sevim
dc.contributor.authorAdiguzel, Aytul
dc.contributor.authorCetinkaya, Hakan
dc.contributor.authorEsen, Seyma
dc.contributor.authorHalis, Duygu
dc.contributor.authorHamparsunoglu, Alis
dc.contributor.authorIlhan, Taha Batuhan
dc.contributor.authorKilicgedik, Atacan
dc.contributor.authorKocer, Oguz
dc.contributor.authorOgur, Salim
dc.contributor.authorOz, Sinan
dc.contributor.authorOzbey, Aydin
dc.contributor.authorOzcan, Veysi Erkcan
dc.contributor.authorUnel, Nafiz Gokhan
dc.date.accessioned2026-06-27T14:46:57Z
dc.date.issued2022
dc.description.abstractKAHVE Laboratory, a particle detector, accelerator, and instrumentation research laboratory located at Bogazici University Kandilli Campus area at Istanbul, is currently working on the design of a RFQ operating at 800 MHz that will accelerate proton beam up to 2 MeV. As a first part of this linear accelerator, a Microwave Discharge Ion Source operating at 2.45 GHz frequency including 20 keV electrode extraction system has been designed, produced, and tested to generate hydrogen plasma and extract proton beams from this plasma medium. To transfer beams to the RFQ cavity, Low Energy Beam Transport (LEBT) line, a beam pipe including 2 solenoid magnets, 2 steerer magnets and a beam diagnostic box between these electromagnets, has been designed and produced, tested separately for now. The beam diagnostic box, including a Faraday cup, a pepper pot plate and there will be a home-built scintillator screen, is designed to measure the current, emittance and profile of the incoming beam. Currently, there has been an upgrade on the ion source. Instead using solenoid electromagnets in order to extract ions from the thermal hydrogen plasma, a new Microwave Discharge Ion Source system has been designed and constructed with permanent magnets. After this permanent magnet configuration upgrade, since the system is operated on the high voltage platform, a higher system stability would be achieved. Permanent magnet profile tests were completed to check the simulation results, then the production of new ion source system was completed, currently it is in the test phase before integrating to the system. In the session, it will be discussed that the simulation & experimental measurement results, and any other details of the whole system, which is constructed at KAHVELab all with local resources. These projects are supported by Istanbul University Scientific Research Commission Project ID 33250 and TUBITAK Project no: 119M774en
dc.description.sponsorshipIstanbul University Scientific Research Commission [33250]
dc.description.sponsorshipTUBITAK [119M774]
dc.identifier.urihttps://hdl.handle.net/20.500.14981/64700
dc.identifier.wos001527471100424
dc.language.isoeng
dc.publisherSISSA Medialab
dc.relation.conference2021 European Physical Society Conference on High Energy Physics-EPS-HEP
dc.relation.ispartofEUROPEAN PHYSICAL SOCIETY CONFERENCE ON HIGH ENERGY PHYSICS, EPS-HEP2021
dc.subjectAstronomy & Astrophysics
dc.subjectPhysics
dc.titleBeam Diagnostics at KAHVE Lab Proton Source and LEBT Line
dc.typeProceedings Paper
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar