Yayın:
Are Bismuth Shields Useful in Dentomaxillofacial Radiology Practice for the Protection of Eyes and Thyroid Glands from Ionizing Radiation?

dc.contributor.authorAytugar, Emre
dc.contributor.authorKose, Taha Emre
dc.contributor.authorGumru, Birsay
dc.contributor.authorAytugar, Tugce Bicer
dc.contributor.authorYasar, Dogan
dc.contributor.authorCene, Erhan
dc.contributor.authorMihmanli, Ahmet
dc.date.accessioned2026-06-27T14:16:05Z
dc.date.issued2018
dc.description.abstractBackground: The eye lens and thyroid gland are sensitive to radiation and have a risk of being exposed to primary beams and scattered radiation during dental radiographic examinations. Objectives: The present study was aimed to evaluate the effectiveness of bismuth shielding in decreasing eye lens and thyroid radiation dose in periapical radiography (PR), orthopantomography (OPTG), and cone beam computed tomography (CBCT) examinations. There is no information in relevant literature regarding the use of bismuth shielding in dental radiology. Materials and Methods: Dose measurements for PR, OPTG and CBCT were conducted by placing thermoluminescent dosimeter chips on the eye and thyroid location in a standard head phantom. Each one of the scan techniques was performed without any bismuth shielding, and they were then repeated with bismuth shielding in place. The percent dose reduction from bismuth shielding was calculated by dividing the dose measured with bismuth shielding by the dose measured without bismuth shielding. Results: The eye dose was observed to decrease in bismuth shielding group in PR, however it was not statistically significant. The thyroid dose was found to be significantly decreased in PR (P 0.05). Conclusion: This study demonstrated higher thyroid and eye lens dose with the use of bismuth shielding in OPTG and CBCT scanning. However, due to the significantly decreased thyroid dose in PR, it may be recommended as an alternative to leaded shielding in periapical radiographic examinations.en
dc.description.urihttps://doi.org/10.5812/iranjradiol.40723
dc.identifier.doi10.5812/iranjradiol.40723
dc.identifier.eissn2008-2711
dc.identifier.issn1735-1065
dc.identifier.issue3
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58647
dc.identifier.volume15
dc.identifier.wos000440678500001
dc.language.isoeng
dc.publisherKOWSAR PUBL
dc.relation.ispartofIRANIAN JOURNAL OF RADIOLOGY
dc.rightsopenAccess
dc.subjectPeriapical Radiography
dc.subjectPanoramic Radiography
dc.subjectCone Beam Computed Tomography
dc.subjectBismuth Shielding
dc.subjectDose Reduction
dc.subjectCT
dc.subjectBREAST
dc.subjectRadiology, Nuclear Medicine & Medical Imaging
dc.titleAre Bismuth Shields Useful in Dentomaxillofacial Radiology Practice for the Protection of Eyes and Thyroid Glands from Ionizing Radiation?
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar