Yayın:
Synthesis and grafting of diazonium tosylates for thermoplastic electrode immunosensors

dc.contributor.authorMcCord, Cynthia P.
dc.contributor.authorOzer, Tugba
dc.contributor.authorHenry, Charles S.
dc.date.accessioned2026-06-27T14:38:51Z
dc.date.issued2021
dc.description.abstractFor electrochemical immunosensors, inexpensive electrodes with fast redox kinetics, and simple stable methods of electrode functionalization are vital. However, many inexpensive and easy to fabricate electrodes suffer from poor redox kinetics, and functionalization can often be difficult and/or unstable. Diazonium tosylates are particularly stable soluble salts that can be useful for electrode functionalization. Recently developed thermoplastic electrodes (TPEs) have been inexpensive, moldable, and highly electroactive carbon composite materials. Herein, the synthesis and grafting of diazonium tosylate salts were optimized for modification of TPEs and used to develop the first TPE immunosensors. With diazonium tosylates, TPEs were amine functionalized either directly through grafting of p-aminophenyl diazonium salt or indirectly through grafting p-nitrophenyl diazonium salt followed by electrochemical reduction to an amine. Diazonium tosylates were synthesized in situ as a paste in 6 min. Once the reaction paste was spread over the electrodes, near monolayer coverage (1.0 +/- 0.2 nmol cm(-2)) was achieved for p-nitrophenyl diazonium salt within 5 min. Amine functionalized electrodes were conjugated to C-reactive protein (CRP) antibodies. Antibody-modified TPEs were applied for the sensitive detection of CRP, a biomarker of cardiovascular disease using electrochemical enzyme-linked immunosorbent assays (ELISA). LODs were determined to be 2 ng mL(-1) in buffer, with high selectivity against interfering species for both functionalization methods. The direct p-aminophenyl modification method had the highest sensitivity to CRP and was further tested in spiked serum with an LOD of 10 ng mL(-1). This low-cost and robust TPE immunosensor platform can be easily adapted for other analytes and multiplexed detection.en
dc.description.sponsorshipNational Science Foundation [CHEM1710222]
dc.description.sponsorshipNational Institutes of Health [R21EB030349]
dc.description.sponsorshipNational Institute of Biomedical Imaging and Bioengineering [R21EB030349] Funding Source: NIH RePORTER
dc.description.urihttps://doi.org/10.1039/d1ay00965f
dc.identifier.doi10.1039/d1ay00965f
dc.identifier.eissn1759-9679
dc.identifier.endpage5064
dc.identifier.issn1759-9660
dc.identifier.issue42
dc.identifier.pubmed34651620
dc.identifier.startpage5056
dc.identifier.urihttps://hdl.handle.net/20.500.14981/63064
dc.identifier.volume13
dc.identifier.wos000707404100001
dc.language.isoeng
dc.publisherROYAL SOC CHEMISTRY
dc.relation.ispartofANALYTICAL METHODS
dc.rightsopenAccess
dc.subjectELECTROCHEMICAL IMMUNOSENSOR
dc.subjectCARBON
dc.subjectBIOSENSORS
dc.subjectSALTS
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.subjectSpectroscopy
dc.titleSynthesis and grafting of diazonium tosylates for thermoplastic electrode immunosensors
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar