Yayın:
Critical organ dose evaluation during interventional stroke imaging: Implications for radiation safety

dc.contributor.authorOzgur, E.
dc.contributor.authorKayaokay, D. Tuncman
dc.contributor.authorOzgur, D. S.
dc.contributor.authorTunay, A.
dc.contributor.authorGunay, O.
dc.contributor.authorKesmezacar, F. F.
dc.contributor.authorDemir, M.
dc.contributor.authorALMisned, G.
dc.contributor.authorTekin, H. O.
dc.date.accessioned2026-06-27T15:38:01Z
dc.date.issued2026
dc.description.abstractIntroduction: Neurointerventional stroke imaging involves prolonged fluoroscopy and multiple angiographic acquisitions, potentially delivering meaningful radiation doses to radiosensitive head and neck organs. This study quantified organ-specific absorbed doses under clinically realistic conditions. Methods: Organ doses were measured using calibrated MTS-100 LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) placed in an Alderson Rando anthropomorphic phantom. Simulated stroke imaging was performed on a Siemens Artis Zee C-arm system using routine clinical parameters. TLDs were calibrated under RQR-9 beam quality at an accredited SSDL and read with a Harshaw 4500 reader. Results: The highest absorbed doses occurred in the left parotid gland and C1-C2 vertebral level. Bilateral thyroid doses averaged similar to 4.6 mGy, and eye lens doses ranged from 5.6 to 11.5 mGy. Dose distribution showed marked spatial variability, reflecting projection geometry and scatter contributions. Conclusion: Although measured single-session doses were below deterministic thresholds, cumulative exposure during repeated or prolonged interventions may become clinically significant. Implications for practice: The findings support the need for strict collimation, optimized projection angles, pulsed fluoroscopy, and continuous dose monitoring to minimize patient and staff exposure while maintaining diagnostic image quality. (c) 2026 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.en
dc.description.sponsorshipPrincess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia [PNURSP2026R149]
dc.description.urihttps://doi.org/10.1016/j.radi.2026.103331
dc.identifier.doi10.1016/j.radi.2026.103331
dc.identifier.eissn1532-2831
dc.identifier.issn1078-8174
dc.identifier.issue4
dc.identifier.pubmed41577541
dc.identifier.urihttps://hdl.handle.net/20.500.14981/72249
dc.identifier.volume32
dc.identifier.wos001764223600001
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofRADIOGRAPHY
dc.subjectRadiation safety
dc.subjectStroke imaging
dc.subjectALARA
dc.subjectClinical dosimetry
dc.subjectRadiology, Nuclear Medicine & Medical Imaging
dc.titleCritical organ dose evaluation during interventional stroke imaging: Implications for radiation safety
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar