Postfire Damage Assessment of a RC Factory Building

dc.contributor.authorAda, Mehmet
dc.contributor.authorYuzer, Nabi
dc.contributor.authorAyvaz, Yusuf
dc.date.accessioned2026-06-27T14:17:22Z
dc.date.issued2019
dc.description.abstractThis paper presents an assessment of postfire damage of a RC factory building. The fire was limited to the ground floor; thus, the structural elements on the ground floor were fire damaged. Also, some relative displacements were observed at the expansion joints, and long wall cracks were observed on other stories. During the visual assessment, typical fire damage was observed (e.g., spalling, netlike cracks, crumbled plaster, bared or visible reinforcement, and crumbled aggregates). Also, some explosive and thermal expansion-induced damage was observed in and out of the fire-damaged areas. To evaluate the effects of the fire on the concrete, spectrophotometer and compressive strength tests were performed on concrete specimens taken from the building. It is concluded that elevated temperatures due to a fire can cause damage in the fire region, and that it can affect the overall stability of the structure.en
dc.description.urihttps://doi.org/10.1061/(asce)cf.1943-5509.0001319
dc.identifier.doi10.1061/(asce)cf.1943-5509.0001319
dc.identifier.eissn1943-5509
dc.identifier.issn0887-3828
dc.identifier.issue5
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58854
dc.identifier.volume33
dc.identifier.wos000481579700006
dc.language.isoeng
dc.publisherASCE-AMER SOC CIVIL ENGINEERS
dc.relation.ispartofJOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES
dc.subjectElevated temperature
dc.subjectFire damage
dc.subjectCompression strength
dc.subjectReinforced concrete building
dc.subjectConcrete
dc.subjectREINFORCED-CONCRETE SLABS
dc.subjectHIGH-STRENGTH CONCRETE
dc.subjectHIGH-TEMPERATURE
dc.subjectFIRE RESISTANCE
dc.subjectBOND STRENGTH
dc.subjectBEHAVIOR
dc.subjectCOLUMNS
dc.subjectPERFORMANCE
dc.subjectCOVER
dc.subjectBEAMS
dc.subjectConstruction & Building Technology
dc.subjectEngineering
dc.titlePostfire Damage Assessment of a RC Factory Building
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar