Yayın:
Renovating thermal power plant to trigeneration system for district heating/cooling: Evaluation of performance variation

dc.contributor.authorErdem, Hasan Huseyin
dc.contributor.authorAkkaya, Ali Volkan
dc.contributor.authorDagdas, Ahmet
dc.contributor.authorSevilgen, Suleyman Hakan
dc.contributor.authorCetin, Burhanettin
dc.contributor.authorSahin, Bahri
dc.contributor.authorTeke, Ismail
dc.contributor.authorGungor, Cengiz
dc.contributor.authorAtas, Selcuk
dc.contributor.authorBasak, Mehmet Zahit
dc.contributor.institutionauthorÇETİN, Burhanettin
dc.date.accessioned2026-06-27T13:42:45Z
dc.date.issued2015
dc.description.abstractThis paper presents performance assessments of thermal power plant-based co/tri-generation systems for district heating/cooling system. The power plants were originally designed exclusively for the generation of electricity. With respect to the renovation of power plants to co/tri-generation systems, the analysis of performance variations in the systems has been undertaken. For the purpose of simulation analysis, thermodynamic models of the eight thermal power plants have been developed. The performance variations have been evaluated with different performance criteria, including electrical power output, classical thermal efficiency, coefficient of performance and comprehensive thermal efficiency. The comprehensive thermal efficiency takes into account all products (electricity, heating and cooling energy) generated from the power plant-based tri-generation system. The results of analysis show that the comprehensive thermal efficiencies of the eight considered systems range from 49% to 61% in the heating mode, although their generated electrical power amounts decrease slightly. As a result, this type of modification for an existing power plant can greatly benefit the cause of energy efficiency and sustainable development. (C) 2015 Elsevier Ltd. All rights reserved.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [105G099]
dc.description.sponsorshipTurkish Electricity Generation Co. Inc. (EUAS)
dc.description.urihttps://doi.org/10.1016/j.applthermaleng.2015.04.030
dc.identifier.doi10.1016/j.applthermaleng.2015.04.030
dc.identifier.endpage42
dc.identifier.issn1359-4311
dc.identifier.startpage35
dc.identifier.urihttps://hdl.handle.net/20.500.14981/54357
dc.identifier.volume86
dc.identifier.wos000357238200004
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofAPPLIED THERMAL ENGINEERING
dc.subjectThermal power plant
dc.subjectDistrict heating/cooling
dc.subjectCogeneration
dc.subjectTrigeneration
dc.subjectEXERGOECONOMIC ANALYSIS
dc.subjectCOGENERATION SYSTEMS
dc.subjectENERGY
dc.subjectThermodynamics
dc.subjectEnergy & Fuels
dc.subjectEngineering
dc.subjectMechanics
dc.titleRenovating thermal power plant to trigeneration system for district heating/cooling: Evaluation of performance variation
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar