Sizing charts of helical capillary tubes used in refrigeration and air conditioning

dc.contributor.authorChingulpitak, Sukkarin
dc.contributor.authorMahian, Omid
dc.contributor.authorDalkilic, Ahmet Selim
dc.contributor.authorAsirvatham, Lazarus Godson
dc.contributor.authorWongwises, Somchai
dc.date.accessioned2026-06-27T14:23:06Z
dc.date.issued2019
dc.description.abstractThis paper presents new selection and correction factor charts for the sizing of adiabatic helical capillary tubes operating with alternative refrigerants. The mathematical model is based on the conservation of mass, energy, and momentum of fluids in capillary tubes. In the two-phase flow region, the developed model is based on the homogenous flow assumption. It is verified by the accuracy of the results of comparison between simulation results and experimental data in open literature. After the developed model is validated, selection and correction charts that include the important parameters are proposed for sizing adiabatic helical capillary tube. The present charts are proposed for R-134a, R-404A, R-407B, R-407C, and R-410A, and a wide range of operation. These newly developed selection and correction charts can be used to select helical capillary tube size from flow conditions and the mass flow rate or to predict the mass flow rate from capillary tube size and flow condition.en
dc.description.sponsorshipResearch Chair Grant National Science and Technology Development Agency (NSTDA)
dc.description.sponsorshipThailand Research Fund (TRF)
dc.description.sponsorshipKing Mongkut's University of Technology Thonburi through the KMUTT 55th Anniversary Commemorative Fund
dc.description.urihttps://doi.org/10.1080/23744731.2018.1490131
dc.identifier.doi10.1080/23744731.2018.1490131
dc.identifier.eissn2374-474X
dc.identifier.endpage10
dc.identifier.issn2374-4731
dc.identifier.issue1
dc.identifier.startpage1
dc.identifier.urihttps://hdl.handle.net/20.500.14981/59991
dc.identifier.volume25
dc.identifier.wos000458654200001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofSCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT
dc.subjectNUMERICAL-SIMULATION
dc.subjectFLOW CHARACTERISTICS
dc.subjectSEPARATED FLOW
dc.subjectMODEL
dc.subjectPERFORMANCE
dc.subjectR-134A
dc.subjectThermodynamics
dc.subjectConstruction & Building Technology
dc.subjectEngineering
dc.titleSizing charts of helical capillary tubes used in refrigeration and air conditioning