Yayın:
Implementation of Three-Phase Grid-Connected Inverter Controlled with dSPACE DS1103

dc.contributor.authorIsen, Evren
dc.contributor.authorYanik, Gurcan
dc.contributor.authorBakan, A. Faruk
dc.contributor.institutionauthorBAKAN, Ahmet Faruk
dc.date.accessioned2026-06-27T13:21:50Z
dc.date.issued2013
dc.description.abstractIn this paper, realization of three-phase grid-connected inverter controlled with dSPACE DS1103 control board is presented. Detailed information about power circuit, sensor board, signal isolation board and DS1103 is given in the paper. The inverter is controlled with DS1103 control board, programming the DSP via MATLAB/Simulink. Connection between the developed control algorithm in Simulink and experimental setup is made with installed DS1103 tools in Simulink. Space vector pulse width modulation technique in d-q synchronous reference frame is used to control the three-phase inverter. The transferred power to grid is 10 kW via three-phase inverter. The injected grid current has 3.59% THD value with 9 kHz switching frequency and 3 mH filter inductance.en
dc.identifier.endpage417
dc.identifier.isbn978-1-4799-1464-7
dc.identifier.issn2377-6897
dc.identifier.startpage413
dc.identifier.urihttps://hdl.handle.net/20.500.14981/52217
dc.identifier.wos000353637100070
dc.language.isoeng
dc.publisherIEEE
dc.relation.conferenceInternational Conference on Renewable Energy Research and Applications (ICRERA)
dc.relation.ispartof2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA)
dc.subjectDS1103
dc.subjectgrid-connected inverter
dc.subjectspace vector pulse width modulation
dc.subjectthree-phase inverter
dc.subjectEnergy & Fuels
dc.titleImplementation of Three-Phase Grid-Connected Inverter Controlled with dSPACE DS1103
dc.typeProceedings Paper
dspace.entity.typePublication