Yayın:
Radiation dose assessment to abdominal and pelvic organs in fluoroscopy-guided lumbar epidural steroid injections: A phantom-based analysis

dc.contributor.authorTunay, Abdurrahman
dc.contributor.authorToptas, Mehmet
dc.contributor.authorKesmezacar, Fahrettin Fatih
dc.contributor.authorKayaokay, Duygu Tuncman
dc.contributor.authorGunay, Osman
dc.contributor.authorKaracam, Songul
dc.contributor.authorOksuz, Didem Colpan
dc.contributor.authorDemir, Mustafa
dc.contributor.authorAlMisned, Ghada
dc.contributor.authorTekin, H. O.
dc.date.accessioned2026-06-27T15:26:20Z
dc.date.issued2026
dc.description.abstractThis study aims to quantify organ-specific radiation doses during transforaminal lumbar epidural steroid injections (ESI) performed under C-arm fluoroscopic guidance using a phantom-based experimental setup. An Alderson Rando anthropomorphic phantom was used to simulate the human anatomy. A total of 32 MTS-100 thermoluminescent dosimeters (LiF:Mg,Ti) were placed at predefined anatomical sites representing abdominal and pelvic organs. Fluoroscopy was conducted using a Siemens Artis Zee system with standard clinical protocols at gantry angles of 0 degrees, 45 degrees, and 180 degrees. The absorbed doses were measured, and organ-specific distributions were analysed. The highest radiation doses were recorded in the left kidney, pancreas, and spleen. Reproductive organs such as the upper ovaries and uterus also received moderate exposure, while the bladder and medulla spinalis received the lowest doses. It can be concluded that even the fluoroscopic beam is localized to the lumbar spine, scattered radiation can result in significant exposure to critical organs, which underlines the importance of optimized imaging protocols and targeted radiation protection measures.en
dc.description.urihttps://doi.org/10.1016/j.radphyschem.2025.113272
dc.identifier.doi10.1016/j.radphyschem.2025.113272
dc.identifier.eissn1879-0895
dc.identifier.issn0969-806X
dc.identifier.urihttps://hdl.handle.net/20.500.14981/70992
dc.identifier.volume239
dc.identifier.wos001564152900001
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofRADIATION PHYSICS AND CHEMISTRY
dc.subjectFluoroscopy-guided injection
dc.subjectThermoluminescent dosimetry (TLD)
dc.subjectAlderson Rando phantom
dc.subjectOrgan dose assessment
dc.subjectRadiation protection
dc.subjectMANAGING CHRONIC PAIN
dc.subjectMEDICARE POPULATION
dc.subjectPHYSICS
dc.subjectChemistry
dc.subjectNuclear Science & Technology