Yayın:
Determination of trace amounts of copper in tap water samples with a calix[4]arene modified carbon paste electrode by differential pulse anodic stripping voltammetry

dc.contributor.authorCanpolat, Esra Celik
dc.contributor.authorSar, Erdem
dc.contributor.authorCoskun, Naciye Yilmaz
dc.contributor.authorCankurtaran, Husnu
dc.contributor.institutionauthorCANKURTARAN, Hüsnü
dc.date.accessioned2026-06-27T13:00:23Z
dc.date.issued2007
dc.description.abstractA calix[4]arene modified carbon paste electrode was used for trace determination of copper. The study of the preconcentration of copper as well as the other heavy metal ions at the modified electrode, with subsequent measurement by differential pulse anodic stripping voltammetry (DPASV), indicates the efficient open-circuit accumulation of the analytes onto the electrode. Many parameters such as the composition of the paste, pH, preconcentration time and stirring rate influence the response of the measurement. The procedure was optimized for copper determination. For a 10-minute preconcentration time at pH 6.5 - 7.5, the detection limit (LOD) was 1.1 mu g L-1. The optimized method was successfully applied to the determination of copper in tap water sample by means of standard addition procedure. The copper content of the sample was comparable with the result obtained with AAS method.en
dc.description.urihttps://doi.org/10.1002/elan.200603829
dc.identifier.doi10.1002/elan.200603829
dc.identifier.eissn1521-4109
dc.identifier.endpage1115
dc.identifier.issn1040-0397
dc.identifier.issue10
dc.identifier.startpage1109
dc.identifier.urihttps://hdl.handle.net/20.500.14981/48877
dc.identifier.volume19
dc.identifier.wos000246836400012
dc.language.isoeng
dc.publisherWILEY-V C H VERLAG GMBH
dc.relation.ispartofELECTROANALYSIS
dc.subjectcalix[4]arene
dc.subjectcarbon paste electrode
dc.subjectstripping voltammetry
dc.subjectheavy metals
dc.subjecttap water
dc.subjectCHEMICALLY-MODIFIED ELECTRODES
dc.subjectPRINTED ELECTROCHEMICAL SENSORS
dc.subjectSELECTIVE COMPLEXATION
dc.subjectANALYTICAL-CHEMISTRY
dc.subjectMETAL-IONS
dc.subjectCALIXARENES
dc.subjectLEAD
dc.subjectCADMIUM
dc.subjectELECTROANALYSIS
dc.subjectCALIX<4>ARENES
dc.subjectChemistry
dc.subjectElectrochemistry
dc.titleDetermination of trace amounts of copper in tap water samples with a calix[4]arene modified carbon paste electrode by differential pulse anodic stripping voltammetry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar